Thd sku 483900 simpson strong tie ecclr l shape end column cap for 6x post 6x beams skewed right ecclr666 the home depot.
Simpson eccl column cap.
Ccos minimum column diameter is 3.
Cco ecco column cap only no straps may be ordered for field welding to pipe or other columns.
Cco ecco dimensions are the same as cc ecc.
5 1 2 beams x 5 1 2 posts fasteners.
Ecc end column caps function similar to cc column caps but are specifically designed to be used in applications where the beam needs to be flush against an exterior wall.
Simpson gray paint dimensions.
Simpson strong tie eccll666 end corner column caps provide a left connection between 2 6x beams and 1 6 x 6 posts when both beams end at the post.
Whether working on a home project or building a structure to comply with building codes go with the choice of engineers and contractors go with genuine simpson strong tie connectors.
Eccl end column caps provide design solutions for this application.
Ccob any two ccos may be specified for back to back welding to create a cross beam connector.
6 5 8 x 7 machine bolt beam post eccll666 information and installation instructions.
Assembled with certified welds for confidence in strength and loading.
Simpson strong tie column cap for 6 x 6 lumber made with 3 gauge steel for strength and durability and assembled with certified welds for confidence in strength and loading.
Max column cap plate thickness 1 2 and 3 16 min.
Column to beam connections often have multiple beams framing on top of a column.
Use the table loads.
Whether working on a home project or building a structure to comply with building codes go with the choice of engineers and contractors go with genuine simpson strong tie connectors.
Screws are configured to provide high uplift design values.
All pipe columns need to be designed by a qualified designer.
The design uses strong drive sds heavy duty connector screws to provide faster installation and a lower profile compared to standard through bolts.
The ecclq cccq and cctq column caps provide strong multiple beam to column connector options.
Column caps a strong beam to column connection installed with strong drive sds heavy duty connector screws to provide faster installation and a greater net section area of the column compared to bolts.
The load is no greater than the lesser element employed.
An ecclr66 with w 3 3 5 8 h 2 7 1 2 is an ecc66 end column cap with a 4x beam on the right side specify direction left or right for stirrup and stirrup seat 1 below the cap seat.
The ccos must be attached to the column cap plate with 4 ccos self tapping screws through the end plate and into the bottom of the ccos.